CONTACT GET A QUOTE MY ACCOUNT
N2N AERO E

N2N AERO E

HEAT RECOVERY VENTILATION WITH ENTHALPY EXCHANGER

Central heat recovery ventilation unit for the whole house. Recovers both heat and moisture from the extract air and prevents dry indoor air in winter. Electric preheater built in.

410 / 720AIRFLOW m³/h
up to 84 %TEMPERATURE EFFICIENCY
26 dB(A)E350 · 3 m
AENERGY CLASS
ENTHALPY EXCHANGER

Recovers both heat and moisture. Prevents dry indoor air in winter and produces minimal condensate.

BUILT-IN PREHEATER

The built-in electric preheater protects the exchanger from freezing down to −25 °C.

QUIET OPERATION

EPP casing with 45 mm insulation and low-energy EC fans.

SMART CONTROL

Wi-Fi and app, weekly schedule, Boost, automatic bypass, Modbus RTU.

KEY FEATURES

Innovative enthalpy exchanger

Maintains healthy humidity in the home (up to 79 % recovery) and prevents dry winter air. The built-in preheater protects it from freezing.

Quiet operation, high savings

High-quality EPP insulation and advanced EC fans ensure exceptionally quiet operation, with stable airflow and low energy use (class A).

Intelligent Smart control

Built-in Wi-Fi lets you control the unit from anywhere via a smartphone app. Ventilation can be fully automated based on sensors or the weather.

PERFORMANCE AND ENERGY

Data for both sizes. The L or R version only determines the spigot layout.

PARAMETERUNITAERO E350AERO E550
Airflow (max.)m³/h410720
Temperature efficiency (max.)%8480
Moisture recovery efficiency (max.)%7956
Energy efficiency class (SEC)AA
Exchanger typecounterflow enthalpycounterflow enthalpy
Power supplyV / Hz1~230 / 501~230 / 50
Fan power input (max.)W213346
Electric preheater (built-in)W10501400
Total power input (max.)W12631746
Fan / preheater currentA1,62 / 4,662,4 / 6,21
Total current (max.)A6,288,61
Sound pressure at a distance of 3 mdB(A)2638

Temperature efficiency and moisture recovery efficiency are maximum values at low airflow. Sound pressure: free field, 3 m, 70 % airflow and 50 Pa.

DESIGN AND OPERATION

PARAMETERUNITAERO E350AERO E550
Conveyed air temperature°C−25 to +40−25 to +40
Temperature at installation location°C+1 to +40+1 to +40
Filters (supply / extract)G4 / G4G4 / G4
Bypass100 %, automatic100 %, automatic
Casing material and insulationEPP, 45 mmEPP, 45 mm
Connection spigot diametermmØ160Ø200
Dimensions W × D × Hmm770 × 616 × 880830 × 711 × 885
Weightkg2655,5
Condensate outletmmØ18Ø18
Protection rating (unit with ducts / motors)IP22 / IP44IP22 / IP44
ControlWi-Fi, app, ModbusWi-Fi, app, Modbus
VersionL / RL / R

We will design a tailor-made solution for you

Tell us whether you are building or renovating and how many rooms you have. We will prepare a design and a price — free of charge and with no obligation.

NO-OBLIGATION QUOTE
Free quote
Free quote